New. Works with the following:
F32T8/WM
#of lamps:1
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
43  W
0.36  A
1.37
3
0.99
10
-22  °F
277  V
43  W
0.17  A
1.37
3
0.94
10
-22  °F
#of lamps:2
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
69  W
0.58  A
1.18
2
0.99
10
-22  °F
277  V
68  W
0.26  A
1.18
2
0.97
10
-22  °F
F17T8
#of lamps:1
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
29  W
0.24  A
1.37
5
0.99
10
-22  °F
System Spec
277  V
29  W
0.12  A
1.37
5
0.89
10
-22  °F
System Spec
#of lamps:2
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
41  W
0.35  A
1.17
3
0.99
10
-22  °F
System Spec
277  V
41  W
0.16  A
1.17
3
0.94
10
-22  °F
System Spec
F25T12
#of lamps:1
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
40  W
0.33  A
1.36
3
0.99
10
-22  °F
System Spec
277  V
40  W
0.15  A
1.36
3
0.94
10
-22  °F
System Spec
#of lamps:2
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
277  V
62  W
0.23  A
1.11
2
0.97
10
-22  °F
System Spec
120  V
63  W
0.52  A
1.11
2
0.99
10
-22  °F
System Spec
F28T8
#of lamps:1
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
277  V
41  W
0.16  A
1.34
3
0.93
10
-22  °F
System Spec
120  V
40  W
0.34  A
1.34
3
0.99
10
-22  °F
System Spec
#of lamps:2
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
65  W
0.55  A
1.14
2
0.99
10
-22  °F
System Spec
277  V
64  W
0.24  A
1.14
2
0.97
10
-22  °F
System Spec
F32T8/25W
#of lamps:1
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
277  V
33  W
0.0  A
1.34
4
0.97
10
-22  °F
System Spec
#of lamps:2
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
277  V
60  W
0.0  A
1.18
2
0.98
10
-22  °F
System Spec
F29T8
#of lamps:1
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
43  W
0.36  A
1.34
1.0
277  V
42  W
0.16  A
1.34
0.94
#of lamps:2
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
68  W
0.57  A
1.15
1.0
277  V
67  W
0.25  A
1.15
0.97
F25T8/WM
#of lamps:1
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
32  W
0.27  A
1.46
4
1.0
10
-22  °F
System Spec
277  V
32  W
0.13  A
1.46
4
0.91
10
-22  °F
System Spec
FE15T8
#of lamps:1
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
25  W
0.2  A
1.21
5
0.99
10
-22  °F
System Spec
277  V
25  W
0.1  A
1.21
5
0.85
10
-22  °F
System Spec
#of lamps:2
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
33  W
0.28  A
1.02
3
0.99
10
-22  °F
System Spec
277  V
33  W
0.13  A
1.02
3
0.9
10
-22  °F
System Spec
F40T8
#of lamps:1
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
56  W
0.46  A
0.66
1
0.99
10
-22  °F
System Spec
277  V
55  W
0.21  A
0.66
1
0.96
10
-22  °F
System Spec
F17T8WM
#of lamps:1
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
26  W
0.22  A
1.57
5
0.99
10
-22  °F
277  V
26  W
0.11  A
1.57
5
0.88
10
-22  °F
#of lamps:2
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
36  W
0.31  A
1.17
3
1.0
10
-22  °F
277  V
36  W
0.14  A
1.17
3
0.93
10
-22  °F
F31T8
#of lamps:1
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
45  W
0.38  A
1.42
1.0
System Spec
277  V
45  W
0.17  A
1.42
0.95
System Spec
#of lamps:2
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
73  W
0.61  A
1.15
1.0
System Spec
277  V
71  W
0.26  A
1.15
0.98
System Spec
F32T8
#of lamps:1
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
277  V
46  W
0.18  A
1.38
3
0.95
10
-22  °F
System Spec
120  V
47  W
0.4  A
1.38
3
0.99
10
-22  °F
System Spec
#of lamps:2
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
76  W
0.64  A
1.19
2
0.99
10
-22  °F
System Spec
277  V
74  W
0.28  A
1.19
2
0.98
10
-22  °F
System Spec
F25T8WM
#of lamps:2
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
277  V
49  W
0.19  A
1.16
2
0.95
10
-22  °F
120  V
49  W
0.41  A
1.16
2
1.0
10
-22  °F
F25T8
#of lamps:1
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
277  V
37  W
0.14  A
1.37
4
0.92
10
-22  °F
System Spec
120  V
37  W
0.3  A
1.37
4
0.99
10
-22  °F
System Spec
#of lamps:2
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
57  W
0.48  A
1.16
2
0.99
10
-22  °F
System Spec
277  V
57  W
0.21  A
1.16
2
0.96
10
-22  °F
System Spec
F26T8
#of lamps:1
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
40  W
0.34  A
1.31
1.0
System Spec
277  V
40  W
0.16  A
1.31
0.94
System Spec
#of lamps:2
Line Volts
Dimming Levels
System Watts
Nom. Line Current
System Ballast Factor
Ballast Efficacy Factor
Power Factor % (>=)
THD % (<=)
Min. Starting Temp
120  V
61  W
0.51  A
1.11
1.0
System Spec
277  V
60  W
0.23  A
1.11
0.97
System Spec